Page view 50
EN
CR50, CR 65, CR80, CR110, CR140 Troubleshooting
51
Compressor is not running (connected to AC supply)
Poor cooling, interior temperature increases
Unusual noises
Fault Possible cause Remedy
No voltage Interruption in the supply cable Establish a connection
Main switch faulty (if installed) Replace the main switch
Additional supply line fuse has blown
(if installed)
Replace the supply line
fuse
Voltage is present but
the compressor doesn't
run
Ambient temperature too high
Insufficient ventilation and/or air sup-
ply
Move the refrigerator to
another location
Condenser is dirty Clean the condenser
Electric circuit between
the pins in the compres-
sor interrupted
Defective compressor Replace the compressor
Fault Possible cause Remedy
Compressor runs for a
long time/continuously
Ambient temperature too high
Insufficient ventilation and/or air sup-
ply
Move the refrigerator to
another location
Condenser is dirty Clean the condenser
Faulty fan Replace the fan
Compressor runs
intermittently
Battery capacity exhausted Charge the battery
Fault Possible cause Remedy
Loud humming A component of the refrigerant circuit
cannot move freely (touching the wall)
Bend the component
carefully away from the
obstruction
Foreign body jammed between the
cooling unit and the wall
Remove the foreign body
Fan noise
_cr-kuehlschraenke.book Seite 51 Montag, 27. Februar 2012 12:46 12