DE 11 LKW-Splitklimaanlage
Einbauanleitung
EN 30 HGV split air conditioner
Installation manual
FR 49 Climatiseur split pour poids lourds
Notice de montage
ES 68 Equipo de aire acondicionado Split para
camiones
Instrucciones de instalación
IT 87 Impianto di climatizzazione split per
autocarri
Istruzioni di montaggio
NL 107 Split airconditioning voor vrachtwagens
Montagehandleiding
DA 126 Splitklimaanlæg til lastbiler
Installationsvejledning
SV 145 Split-klimatanläggning för lastbilar
Monteringsanvisning
NO 164 Delt klimaanlegg for lastebiler
Montasjeveiledning
FIN 182 Kuorma-auton ilmastointilaite
Asennusohje
SP-900
SP-900-Install.book Seite 1 Montag, 25. Januar 2010 4:53 16
Page view 0
1 2 3 4 5 6 ... 28 29

Summary of Contents

Page 1

DE 11 LKW-SplitklimaanlageEinbauanleitungEN 30 HGV split air conditionerInstallation manualFR 49 Climatiseur split pour poids lourdsNotice de montageE

Page 2

Safety instructionsCoolAir30Contents1 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 3

31Safety instructionsCoolAir1.1 Using the device Only use the air conditioner for the purpose specified by the manufacturer and do not make any alter

Page 4

Conventions in this manualCoolAir322 Conventions in this manual2.1 General information on the installation manualThis installation manual contains th

Page 5

33Proper useCoolAiraThe safety instruction indicates potential hazards which could arise during the installation or operation of the product and caus

Page 6

Scope of deliveryCoolAir344 Scope of deliveryCoolAir SP-9005InstallationaCautionThe air conditioner may only be installed by qualified personnel from

Page 7

35InstallationCoolAir5.2 Notes on installationeWarningMake sure that all electrical components are electrically discharged before carrying out work on

Page 8 - 4441300096

InstallationCoolAir365.3 Installation stepsaCautionThe manufacturer only assumes liability for parts included in the scope of delivery. The validity o

Page 9

37InstallationCoolAir5.3.2 Installing the condenser unitITo install the condenser unit using a vehicle-specific WAECO fastening frame, please observe

Page 10 - 1 Safety instructions

InstallationCoolAir385.3.3 Installing the evaporator unitThe evaporator unit is fitted on the vertical rear panel, near the bunk, in a horizontal posi

Page 11 - 1.1 Using the device

39InstallationCoolAir5.3.4 Connecting the condenser unit to the evaporator unitaCautionAvoid narrow radii during bending. Use a suitable round object

Page 12 - 2 Conventions in this manual

3CoolAir11232SP-900-Install.book Seite 3 Montag, 25. Januar 2010 4:53 16

Page 13 - 3 Proper use

InstallationCoolAir40IThe connection lines should be installed at right angles to the rear panel of the lorry (see Fig. 12 on page 7). For this purp

Page 14 - 5Installation

41InstallationCoolAir5.3.5 Installing and connecting the power cableIWe recommend that you connect the power cable to the fuse box or terminal block i

Page 15 - 5.2 Notes on installation

InstallationCoolAir42ICheck the voltage drop between the vehicle connection and the cable connector on the compressor. The voltage drop must not excee

Page 16 - 5.3 Installation steps

43ConfigurationCoolAir6 ConfigurationBefore you first start up the system, you can adapt the controls according to the installation conditions. This m

Page 17

ConfigurationCoolAir446.2 Menu level 1: Set temperatureThe system always starts with a defined value for the room temperature. This parameter can be c

Page 18

45ConfigurationCoolAir➤ Use the Temp. + and - buttons (fig. 184 or 5) to select the low voltage cut-off value. The characteristic figures at second an

Page 19

ConfigurationCoolAir466.5 Menu level 4: Default settingYou can reset the parameters you set in configuration mode at menu levels 1 to 3 to the default

Page 20

47Maintenance and careCoolAir7 Maintenance and careaCautionDo not use abrasive cleaning agents or hard objects during cleaning as these can damage the

Page 21

Technical dataCoolAir488 Technical dataVersions, technical modifications and delivery options reserved.CoolAir SP-900 air conditioner Item number 910

Page 22

Europe Dometic Austria GmbHNeudorferstrasse 1082353 Guntramsdorf℡ +43 2236 908070 +43 2236 90807060Mail: [email protected] Switzerland AGRiedacker

Page 23 - 6 Configuration

CoolAir434SP-900-Install.book Seite 4 Montag, 25. Januar 2010 4:53 16

Page 24

5CoolAir567SP-900-Install.book Seite 5 Montag, 25. Januar 2010 4:53 16

Page 25

CoolAir68910SP-900-Install.book Seite 6 Montag, 25. Januar 2010 4:53 16

Page 26

7CoolAir111213SP-900-Install.book Seite 7 Montag, 25. Januar 2010 4:53 16

Page 27 - 7 Maintenance and care

CoolAir814SP-900-Install.book Seite 8 Montag, 25. Januar 2010 4:53 16

Page 28 - 8 Technical data

9CoolAirC+TF-C+F++1234wbrgrgl-wbrglgr444130010844413001084441300097444130009744413000964441300096swro+-swroroglblrobrbrro+-15bl br gl gr ro sw wDE Bla

Page 29 - Overseas + Middle East

CoolAir10161718156234897SP-900-Install.book Seite 10 Montag, 25. Januar 2010 4:53 16