Page view 14
Disposal HDC-161, HDC-221
16
9 Disposal
Place the packaging material in the appropriate recycling waste bins
wherever possible.
If you wish to finally dispose of the device, ask your local recycling
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
10 Troubleshooting
Compressor does not run
(See table on page 11)
Fault Possible cause Remedy
U
T
= 0 V The connection between the battery
and the electronics is interrupted
Establish a connection
Main switch defective (if installed) Replace the main switch
Additional supply line fuse has blown
(if installed)
Replace the fuse
U
T
U
ON
Battery voltage is too low Charge the battery
Start attempt with
U
T
U
OFF
Loose cables
Poor contact (corrosion)
Establish a connection
Battery capacity too low Replace the battery
Cable cross section too low Replace the cable
(3, page 4)
Start attempt with
U
T
U
ON
Ambient temperature too high
Insufficient ventilation Move the refrigerator
Condensor is dirty Clean the condensor
Fan defective (if installed) Replace the fan
Electric circuit between
the pins in the
compressor interrupted
Defective compressor Replace the compressor
U
T
Voltage between the positive and negative electronic terminals
U
ON
Switch-on voltage of the electronics
U
OFF
Switch-off voltage of the electronics
hdc161-221.book Seite 16 Donnerstag, 2. September 2010 9:44 09